Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2024-9832— No limit on failed login attempts with Clinician Password or Serial Number Clinician Password on Life2000 Ventilator

CVSS 9.3 · Critical EPSS 0.09% · P25
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2024-9832

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
No limit on failed login attempts with Clinician Password or Serial Number Clinician Password on Life2000 Ventilator
Source: NVD (National Vulnerability Database)
Vulnerability Description
There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execute a brute-force attack to gain unauthorized access to the ventilator, and then make changes to device settings that could disrupt the function of the device and/or result in unauthorized information disclosure.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
过多认证尝试的限制不恰当
Source: NVD (National Vulnerability Database)
Vulnerability Title
Baxter Life2000 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Baxter Life2000是Baxter公司的一款无需面罩的无创呼吸机。 Baxter Life2000存在安全漏洞,该漏洞源于使用临床医生密码或序列号临床医生密码允许的登录失败次数没有限制,攻击者可以执行暴力攻击以获得对呼吸机的未经授权的访问权限。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Shenlong Deep Dive — AI Deep Analysis

10-question deep dive: root cause, exploitation, mitigation, urgency. Read summary free, full version requires login.

Affected Products

VendorProductAffected VersionsCPESubscribe
BaxterLife2000 Ventilation System 06.08.00.00 and prior -

II. Public POCs for CVE-2024-9832

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-9832

登录查看更多情报信息。

Same Patch Batch · Baxter · 2024-11-14 · 8 CVEs total

CVE-2024-4896610.0 CRITICALLife2000 service tools for test and calibration do not support user authentication
CVE-2024-4896710.0 CRITICALLife2000 ventilator and Service PC lack sufficient audit logging capabilities
CVE-2024-98349.3 CRITICALImproper data protection on Life2000 ventilator serial interface
CVE-2024-489749.3 CRITICALLife2000 Ventilator does not perform proper file integrity checks when adopting firmware u
CVE-2024-489719.3 CRITICALClinician Password and Serial Number Clinician Password are hard-coded in Life2000 Ventila
CVE-2024-489709.3 CRITICALLife2000 Ventilator microcontroller lacks memory protection
CVE-2024-489739.3 CRITICALDebug port on Life2000 Ventilator serial interface is enabled by default

IV. Related Vulnerabilities

V. Comments for CVE-2024-9832

No comments yet


Leave a comment