Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

Delta Electronics — Vulnerabilities & Security Advisories 223

Browse all 223 CVE security advisories affecting Delta Electronics. AI-powered Chinese analysis, POCs, and references for each vulnerability.

Delta Electronics operates primarily as a manufacturer of power electronics and automation solutions, supplying critical infrastructure components such as variable frequency drives, uninterruptible power supplies, and industrial controllers. The company’s extensive product portfolio, particularly within industrial control systems, has historically exposed it to a significant number of security flaws, with 223 CVEs currently documented. Common vulnerability classes affecting these devices include remote code execution, cross-site scripting, and privilege escalation, often stemming from weak authentication mechanisms or unpatched firmware in legacy industrial protocols. While no single catastrophic global incident has been widely publicized, the sheer volume of disclosed vulnerabilities highlights systemic challenges in securing embedded systems used in critical infrastructure. This pattern underscores the ongoing difficulty in maintaining robust security postures for hardware deeply integrated into operational technology environments, where updates are frequently delayed or difficult to implement.

Found 31 results / 223Clear Filters
CVE IDTitleCVSSSeverityPublished
CVE-2024-10456 Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data — InfraSuite Device MasterCWE-502 9.8 Critical2024-10-30
CVE-2023-47279 Delta Electronics InfraSuite Device Master Path Traversal — InfraSuite Device MasterCWE-22 7.5 High2023-11-30
CVE-2023-47207 Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data — InfraSuite Device MasterCWE-502 9.8 Critical2023-11-30
CVE-2023-46690 Delta Electronics InfraSuite Device Master Path Traversal — InfraSuite Device MasterCWE-35 8.8 High2023-11-30
CVE-2023-39226 Delta Electronics InfraSuite Device Master Exposed Dangerous Method Or Function — InfraSuite Device MasterCWE-749 9.8 Critical2023-11-30
CVE-2023-30765 ​Delta Electronics InfraSuite Device Master Improper Access Control — Infrasuite Device MasterCWE-269 8.8 High2023-07-10
CVE-2023-34316 Delta Electronics InfraSuite Device Master Improper Access Control — Infrasuite Device MasterCWE-552 6.5 Medium2023-07-10
CVE-2023-34347 ​Delta Electronics InfraSuite Device Master Deserialization of Untrusted Data — Infrasuite Device MasterCWE-502 9.8 Critical2023-07-10
CVE-2023-1135 Delta Electronics InfraSuite Device Master 安全漏洞 — InfraSuite Device MasterCWE-732 7.8 High2023-03-27
CVE-2023-1145 Delta Electronics InfraSuite Device Master 代码问题漏洞 — InfraSuite Device MasterCWE-502 7.8 High2023-03-27
CVE-2023-1140 CVE-2023-1140 — InfraSuite Device Master 9.8 Critical2023-03-27
CVE-2023-1141 CVE-2023-1141 — InfraSuite Device Master 8.8 High2023-03-27
CVE-2023-1136 CVE-2023-1136 — InfraSuite Device Master 9.8 Critical2023-03-27
CVE-2023-1142 CVE-2023-1142 — InfraSuite Device Master 7.5 High2023-03-27
CVE-2023-1134 CVE-2023-1134 — InfraSuite Device Master 7.1 High2023-03-27
CVE-2023-1143 CVE-2023-1143 — InfraSuite Device Master 8.8 High2023-03-27
CVE-2023-1137 CVE-2023-1137 — InfraSuite Device Master 6.5 Medium2023-03-27
CVE-2023-1144 CVE-2023-1144 — InfraSuite Device Master 8.8 High2023-03-27
CVE-2023-1138 CVE-2023-1138 — InfraSuite Device Master 7.5 High2023-03-27
CVE-2023-1139 CVE-2023-1139 — InfraSuite Device Master 8.8 High2023-03-27
CVE-2023-1133 CVE-2023-1133 — InfraSuite Device Master 9.8 Critical2023-03-27
CVE-2022-41778 Delta Electronics InfraSuite Device Master 代码问题漏洞 — InfraSuite Device MasterCWE-502 9.8 Critical2023-01-12
CVE-2022-41629 Delta Electronics InfraSuite Device Master 访问控制错误漏洞 — InfraSuite Device MasterCWE-306 7.5 High2022-10-31
CVE-2022-41776 Delta Electronics InfraSuite Device Master 访问控制错误漏洞 — InfraSuite Device MasterCWE-306 7.5 High2022-10-31
CVE-2022-41644 Delta Electronics InfraSuite Device Master 访问控制错误漏洞 — InfraSuite Device MasterCWE-306 8.8 High2022-10-31
CVE-2022-41688 Delta Electronics InfraSuite Device Master 访问控制错误漏洞 — InfraSuite Device MasterCWE-306 9.8 Critical2022-10-31
CVE-2022-40202 Delta Electronics InfraSuite Device Master 访问控制错误漏洞 — InfraSuite Device MasterCWE-306 9.8 Critical2022-10-31
CVE-2022-41772 Delta Electronics InfraSuite Device Master 路径遍历漏洞 — InfraSuite Device MasterCWE-22 9.8 Critical2022-10-31
CVE-2022-41657 Delta Electronics InfraSuite Device Master 路径遍历漏洞 — InfraSuite Device MasterCWE-22 9.8 Critical2022-10-31
CVE-2022-41779 Delta Electronics InfraSuite Device Master 代码问题漏洞 — InfraSuite Device MasterCWE-502 8.8 High2022-10-31

This page lists every published CVE security advisory associated with Delta Electronics. Each entry links to a detailed page with CVSS scoring, CWE classification, affected products and references. AI-generated Chinese analysis is provided for fast triage.