Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2026-26289— Subnet Solutions PowerSYSTEM Center Incorrect Authorization

CVSS 8.2 · High EPSS 0.02% · P6

Possible ATT&CK Techniques 1AI

T1530 · Data from Cloud Storage

Affected Version Matrix 3

VendorProductVersion RangeStatus
Subnet SolutionsPowerSYSTEM Center 20205.8.x≤ 5.28.xaffected
Subnet SolutionsPowerSYSTEM Center 20246.0.x≤ 6.1.xaffected
Subnet SolutionsPowerSYSTEM Center 20267.0.xaffected
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2026-26289

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Source: NVD (National Vulnerability Database)
Vulnerability Description
PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L
Source: NVD (National Vulnerability Database)
Vulnerability Type
授权机制不正确
Source: NVD (National Vulnerability Database)
Vulnerability Title
Subnet Solutions PowerSYSTEM Center 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Subnet Solutions PowerSYSTEM Center是Subnet Solutions公司的一个电力解决方案。 Subnet Solutions PowerSYSTEM Center存在安全漏洞,该漏洞源于设备账户导出的REST API端点存在权限限制不足,可能导致具有有限权限的经过身份验证的用户暴露通常仅限于管理员权限的敏感信息。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Subnet SolutionsPowerSYSTEM Center 2020 5.8.x ~ 5.28.x -
Subnet SolutionsPowerSYSTEM Center 2024 6.0.x ~ 6.1.x -
Subnet SolutionsPowerSYSTEM Center 2026 7.0.x -

II. Public POCs for CVE-2026-26289

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-26289

登录查看更多情报信息。

Same Patch Batch · Subnet Solutions · 2026-05-12 · 4 CVEs total

CVE-2026-355556.3 MEDIUMSubnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-335705.7 MEDIUMSubnet Solutions PowerSYSTEM Center Incorrect Authorization
CVE-2026-355045.5 MEDIUMSubnet Solutions PowerSYSTEM Center CRLF injection

IV. Related Vulnerabilities

V. Comments for CVE-2026-26289

No comments yet


Leave a comment