Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2024-5558

CVSS 6.4 · Medium EPSS 0.07% · P21
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2024-5558

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could cause escalation of privileges when an attacker abuses a limited admin account.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
检查时间与使用时间(TOCTOU)的竞争条件
Source: NVD (National Vulnerability Database)
Vulnerability Title
Schneider Electric SpaceLogic AS-P 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric SpaceLogic AS-P是法国施耐德电气(Schneider Electric)公司的一个自动化服务器。 Schneider Electric SpaceLogic AS-P V5.0.3及之前版本和SpaceLogic AS-B V5.0.3及之前版本存在安全漏洞,该漏洞源于存在竞争条件漏洞,当攻击者滥用受限管理员帐户时可能导致特权升级。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Schneider ElectricSpaceLogic AS-P V5.0.3 and prior -
Schneider ElectricSpaceLogic AS-B V5.0.3 and prior -

II. Public POCs for CVE-2024-5558

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-5558

登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2024-06-12 · 13 CVEs total

CVE-2024-370369.8 CRITICALSchneider Electric SAGE RTUs 缓冲区错误漏洞
CVE-2024-370378.1 HIGHSchneider Electric SAGE RTUs 路径遍历漏洞
CVE-2024-27477.8 HIGHSchneider Electric Easergy Studio 代码问题漏洞
CVE-2024-08657.8 HIGHSchneider Electric EcoStruxure IT Gateway 信任管理问题漏洞
CVE-2024-370387.5 HIGHSchneider Electric SAGE RTUs 安全漏洞
CVE-2024-50566.5 MEDIUMSchneider Electric Modicon M340 安全漏洞
CVE-2024-53136.5 MEDIUMSchneider Electric EVlink Home Smart 安全漏洞
CVE-2024-55596.1 MEDIUMSchneider Electric PowerLogic 安全漏洞
CVE-2024-370395.9 MEDIUMSchneider Electric SAGE RTUs 安全漏洞
CVE-2024-370405.4 MEDIUMSchneider Electric SAGE RTUs 安全漏洞
CVE-2024-55605.3 MEDIUMSchneider Electric SAGE RTUs 缓冲区错误漏洞
CVE-2024-55574.5 MEDIUMSchneider Electric SpaceLogic AS-P 日志信息泄露漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2024-5558

No comments yet


Leave a comment