Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2022-30937

EPSS 0.53% · P67
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2022-30937

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
内存缓冲区边界内操作的限制不恰当
Source: NVD (National Vulnerability Database)
Vulnerability Title
Siemens EN100 Ethernet module 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens EN100 Ethernet module是德国西门子(Siemens)公司的一个以太网模块。 Siemens EN100 Ethernet module 存在安全漏洞,该漏洞源于将特制 HTTP 数据包解析到 /txtrace 端点时包含内存损坏漏洞,攻击者利用该漏洞可以使受影响的应用程序崩溃,以下产品和版本受到影响:EN100 以太网模块 DNP3 IP variant(所有版本)、EN100 以太网模块 IEC 104 variant(所有版本)、EN100 以太网模块 IEC 61
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

II. Public POCs for CVE-2022-30937

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-30937

登录查看更多情报信息。

Same Patch Batch · Siemens · 2022-06-14 · 27 CVEs total

CVE-2022-302309.8 CRITICALSiemens SICAM GridEdge Essential 访问控制错误漏洞
CVE-2022-322518.8 HIGHSiemens SINEMA Remote Connect Server 访问控制错误漏洞
CVE-2022-322628.8 HIGHSiemens SINEMA Remote Connect Server命令注入漏洞
CVE-2022-302288.8 HIGHSiemens SICAM GridEdge Essential 访问控制错误漏洞
CVE-2022-314657.8 HIGHSiemens Xpedition Designer 安全漏洞
CVE-2022-302297.2 HIGHSiemens SICAM GridEdge Essential 授权问题漏洞
CVE-2022-322596.5 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-322526.5 MEDIUMSiemens SINEMA Remote Connect Server 数据伪造问题漏洞
CVE-2022-322606.5 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-290346.1 MEDIUMSiemens SINEMA Remote Connect Server跨站脚本漏洞
CVE-2022-272215.9 MEDIUMSiemens SINEMA Remote Connect Server 安全特征问题漏洞
CVE-2022-322615.3 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-322555.3 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-322585.3 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-302314.9 MEDIUMSiemens SICAM GridEdge Essential 安全漏洞
CVE-2022-322534.9 MEDIUMSiemens SINEMA Remote Connect Server 输入验证错误漏洞
CVE-2022-322544.3 MEDIUMSiemens SINEMA Remote Connect Server 日志信息泄露漏洞
CVE-2022-322564.3 MEDIUMSiemens SINEMA Remote Connect Server 安全漏洞
CVE-2022-32285Siemens Mendix SAML Module 代码问题漏洞
CVE-2021-37182Siemens SCALANCE 安全漏洞

Showing top 20 of 27 CVEs. View all on vendor page &rarr; →

IV. Related Vulnerabilities

V. Comments for CVE-2022-30937

No comments yet


Leave a comment