Vulnerability Description
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
输入验证不恰当
Source: NVD (National Vulnerability Database)
Vulnerability Title
Siemens多款产品输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens SIMATIC PCS 7等都是德国西门子(Siemens)公司的产品。SIMATIC PCS 7是一套过程控制系统。SIMATIC WinCC是一套自动化的数据采集与监控(SCADA)系统。SPPA-T3000是一套主要用于发电厂的分布式控制系统。 Siemens SIMATIC PCS 7 存在输入验证错误漏洞。远程攻击者可通过向受影响设备的RPC服务发送特制的消息利用该漏洞造成拒绝服务。以下产品和版本受到影响:Siemens OpenPCS 7 7.1及之前版本,8.0版本,8.1版
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
SiemensOpenPCS 7 V7.1 and earlier All versions -
SiemensOpenPCS 7 V8.0 All versions -
SiemensOpenPCS 7 V8.1 All versions < V8.1 Upd5 -
SiemensOpenPCS 7 V8.2 All versions -
SiemensOpenPCS 7 V9.0 All versions < V9.0 Upd1 -
SiemensSIMATIC BATCH V7.1 and earlier All versions -
SiemensSIMATIC BATCH V8.0 All versions < V8.0 SP1 Upd21 -
SiemensSIMATIC BATCH V8.1 All versions < V8.1 SP1 Upd16 -
SiemensSIMATIC BATCH V8.2 All versions < V8.2 Upd10 -
SiemensSIMATIC BATCH V9.0 All versions < V9.0 SP1 -
SiemensSIMATIC NET PC Software V14 All versions < V14 SP1 Update 14 -
SiemensSIMATIC NET PC Software V15 All versions < 15 SP1 -
SiemensSIMATIC PCS 7 V7.1 and earlier All versions -
SiemensSIMATIC PCS 7 V8.0 All versions -
SiemensSIMATIC PCS 7 V8.1 All versions -
SiemensSIMATIC PCS 7 V8.2 All versions < V8.2 SP1 -
SiemensSIMATIC PCS 7 V9.0 All versions < V9.0 SP1 -
SiemensSIMATIC Route Control V7.1 and earlier All versions -
SiemensSIMATIC Route Control V8.0 All versions -
SiemensSIMATIC Route Control V8.1 All versions -
SiemensSIMATIC Route Control V8.2 All versions -
SiemensSIMATIC Route Control V9.0 All versions < V9.0 Upd1 -
SiemensSIMATIC WinCC Runtime Professional V13 All versions < V13 SP2 Upd2 -
SiemensSIMATIC WinCC Runtime Professional V14 All versions < V14 SP1 Upd5 -
SiemensSIMATIC WinCC V7.2 and earlier All versions < WinCC 7.2 Upd 15 -
SiemensSIMATIC WinCC V7.3 All versions < WinCC 7.3 Upd 16 -
SiemensSIMATIC WinCC V7.4 All versions < V7.4 SP1 Upd 4 -
SiemensSPPA-T3000 Application Server All versions < Service Pack R8.2 SP2 -

II. Public POCs for CVE-2018-4832

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2018-4832

登录查看更多情报信息。

IV. Related Vulnerabilities

V. Comments for CVE-2018-4832

No comments yet


Leave a comment