Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1336 CNY

100%

CVE-2026-50034— Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information

CVSS 6.5 · Medium EPSS 0.14% · P4

Affected Version Matrix 1

VendorProductVersion RangeStatus
Apollo PharmacyBlood Glucose Monitoring System (Model No. APG-01 BT)0x0110_v1.1.0affected
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2026-50034

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information
Source: NVD (National Vulnerability Database)
Vulnerability Description
An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Source: NVD (National Vulnerability Database)
Vulnerability Type
敏感数据的明文传输
Source: NVD (National Vulnerability Database)
Vulnerability Title
Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT 加密问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT是Apollo Pharmacy公司的一款蓝牙连接式血糖监测系统。 Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT 0x0110_v1.1.0版本存在加密问题漏洞,该漏洞源于蓝牙低功耗通信范围内的攻击者可被动拦截无线流量并获取敏感健康信息,包括血糖测量值。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Apollo PharmacyBlood Glucose Monitoring System (Model No. APG-01 BT) 0x0110_v1.1.0 -

II. Public POCs for CVE-2026-50034

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-50034

登录查看更多情报信息。

Vendor Advisories for CVE-2026-50034 (2)

Vendor Pages for CVE-2026-50034 (1)

Other References for CVE-2026-50034 (1)