Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2026-23775

CVSS 7.6 · High EPSS 0.02% · P5
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2026-23775

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
Dell PowerProtect Data Domain appliances with Data Domain Operating System (DD OS) of Feature Release versions 8.0 through 8.5, LTS2025 release version 8.3.1.0 through 8.3.1.10 contain an insertion of sensitive information into log file vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to credential exposures. Authentication attempts as the compromised user would need to be authorized by a high privileged DD user. This vulnerability only affects systems with retention lock enabled.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
通过日志文件的信息暴露
Source: NVD (National Vulnerability Database)
Vulnerability Title
Dell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Dell PowerProtect Data Domain(Dell PowerProtect DD)是美国戴尔(Dell)公司的一套用于数据保护、备份、存储和重复数据消除的硬件设备。 Dell PowerProtect Data Domain(Dell PowerProtect DD) 8.5及之前版本、LTS2025 release 8.3.1.10及之前版本存在安全漏洞,该漏洞源于敏感信息插入日志文件,可能导致凭据泄露。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
DellPowerProtect Data Domain appliances 0 ~ 8.6.0.0 or later -

II. Public POCs for CVE-2026-23775

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2026-23775

登录查看更多情报信息。

Same Patch Batch · Dell · 2026-04-17 · 16 CVEs total

CVE-2026-238538.4 HIGHDell PowerProtect Data Domain 安全漏洞
CVE-2025-365687.8 HIGHDell PowerProtect Data Domain 安全漏洞
CVE-2026-237767.2 HIGHDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2026-237787.2 HIGHDell PowerProtect Data Domain 安全漏洞
CVE-2026-350736.7 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2026-350746.7 MEDIUMDell PowerProtect Data Domain 安全漏洞
CVE-2026-350726.7 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2026-351536.7 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2026-237796.7 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2025-466416.6 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2025-466076.6 MEDIUMDell PowerProtect Data Domain 安全漏洞
CVE-2025-466066.2 MEDIUMDell PowerProtect Data Domain 安全漏洞
CVE-2025-466056.2 MEDIUMDell PowerProtect Data Domain(Dell PowerProtect DD) 安全漏洞
CVE-2026-282635.9 MEDIUMDell PowerProtect Data Domain 安全漏洞
CVE-2026-237774.3 MEDIUMDell PowerProtect Data Domain 安全漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2026-23775

No comments yet


Leave a comment