CVE-2025-30512— Growatt Cloud portal External Control of System or Configuration Setting

CVSS 6.5 · Medium EPSS 0.64% · P71
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2025-30512

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Growatt Cloud portal External Control of System or Configuration Setting
Source: NVD (National Vulnerability Database)
Vulnerability Description
Unauthenticated attackers can send configuration settings to device and possible perform physical actions remotely (e.g., on/off).
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Source: NVD (National Vulnerability Database)
Vulnerability Type
系统设置或配置在外部可控制
Source: NVD (National Vulnerability Database)
Vulnerability Title
Growatt Cloud Applications 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Growatt Cloud Applications是中国古瑞瓦特(Growatt)公司的一个监控平台。 Growatt Cloud Applications 3.6.0及之前版本存在安全漏洞,该漏洞源于未经验证的攻击者可远程发送配置设置并可能执行物理操作。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
GrowattCloud portal 0 ~ 3.6.0 -

II. Public POCs for CVE-2025-30512

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-30512

登录查看更多情报信息。

Same Patch Batch · Growatt · 2025-04-15 · 30 CVEs total

CVE-2025-242979.8 CRITICALGrowatt Cloud portal Cross-site Scripting
CVE-2025-305109.8 CRITICALGrowatt Cloud portal Insufficient Type Distinction
CVE-2025-305118.8 HIGHGrowatt Cloud Applications Cross-site Scripting
CVE-2025-279397.5 HIGHGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-313606.5 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-319455.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-279295.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-311475.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-243155.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-302575.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-275615.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-279275.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-248505.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-319505.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-252765.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-275655.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-275755.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-316545.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-277195.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key
CVE-2025-268575.3 MEDIUMGrowatt Cloud portal Authorization Bypass Through User-Controlled Key

Showing top 20 of 30 CVEs. View all on vendor page → →