Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2025-12611— Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow

CVSS 8.8 · High EPSS 0.24% · P47
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2025-12611

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda AC21 SetPptpServerCfg formSetPPTPServer buffer overflow
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability was identified in Tenda AC21 16.03.08.16. This vulnerability affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIp leads to buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
未进行输入大小检查的缓冲区拷贝(传统缓冲区溢出)
Source: NVD (National Vulnerability Database)
Vulnerability Title
Tenda AC21 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda AC21是中国腾达(Tenda)公司的一款无线路由器。 Tenda AC21 16.03.08.16版本存在安全漏洞,该漏洞源于对文件/goform/SetPptpServerCfg中参数startIp的错误操作,可能导致缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
TendaAC21 16.03.08.16 cpe:2.3:o:tenda:ac21_firmware:*:*:*:*:*:*:*:*

II. Public POCs for CVE-2025-12611

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2025-12611

登录查看更多情报信息。

Same Patch Batch · Tenda · 2025-11-03 · 4 CVEs total

CVE-2025-126188.8 HIGHTenda AC8 DatabaseIniSet buffer overflow
CVE-2025-126198.8 HIGHTenda A15 openNetworkGateway fromSetWirelessRepeat buffer overflow
CVE-2025-126228.8 HIGHTenda AC10 SysRunCmd formSysRunCmd buffer overflow

IV. Related Vulnerabilities

V. Comments for CVE-2025-12611

No comments yet


Leave a comment