Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2024-9409

CVSS 7.5 · High EPSS 0.27% · P50
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2024-9409

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
未加控制的资源消耗(资源穷尽)
Source: NVD (National Vulnerability Database)
Vulnerability Title
Schneider Electric多款产品 资源管理错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric PowerLogic PM5320等都是法国施耐德电气(Schneider Electric)公司的一款功率和电能表。 Schneider Electric多款产品存在资源管理错误漏洞,该漏洞源于存在不受控制的资源消耗,可能导致设备无响应,从而导致通信丢失。以下产品及版本受到影响:PowerLogic PM5320 2.3.8及之前版本、PowerLogic PM5340 2.3.8及之前版本和PowerLogic PM5341 2.6.6及之前版本
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Schneider ElectricPowerLogic PM5320 Version 2.3.8 and prior -
Schneider ElectricPowerLogic PM5340 Version 2.3.8 and prior -
Schneider ElectricPowerLogic PM5341 Version 2.6.6 and prior -

II. Public POCs for CVE-2024-9409

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-9409

登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2024-11-13 · 7 CVEs total

CVE-2024-105759.8 CRITICALSchneider Electric EcoStruxure IT Gateway 安全漏洞
CVE-2024-89388.1 HIGHSchneider Electric Modicon M340 缓冲区错误漏洞
CVE-2024-89337.5 HIGHSchneider Electric Modicon M340 安全漏洞
CVE-2024-89357.5 HIGHSchneider Electric Modicon M340 安全漏洞
CVE-2024-89376.5 MEDIUMSchneider Electric Modicon M340 缓冲区错误漏洞
CVE-2024-89366.5 MEDIUMSchneider Electric 输入验证错误漏洞