I. Basic Information for CVE-2024-3879

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Tenda W30E setcfm formSetCfm stack-based overflow
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
栈缓冲区溢出
Source: NVD (National Vulnerability Database)
Vulnerability Title
Tenda W30E 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Tenda W30E是中国腾达(Tenda)公司的一款路由器。 Tenda W30E 1.0.1.25(633)版本存在安全漏洞,该漏洞源于 /goform/setcfm 的formSetCfm函数存在安全问题,通过参数 funcpara1导致基于堆栈的缓冲区溢出。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
TendaW30E 1.0.1.25(633) -

II. Public POCs for CVE-2024-3879

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2024-3879

登录查看更多情报信息。

Same Patch Batch · Tenda · 2024-04-16 · 9 CVEs total

CVE-2024-38748.8 HIGHTenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow
CVE-2024-38758.8 HIGHTenda F1202 Natlimit fromNatlimit stack-based overflow
CVE-2024-38768.8 HIGHTenda F1202 VirtualSer fromVirtualSer stack-based overflow
CVE-2024-38778.8 HIGHTenda F1202 fromqossetting stack-based overflow
CVE-2024-38788.8 HIGHTenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
CVE-2024-38818.8 HIGHTenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow
CVE-2024-38828.8 HIGHTenda W30E fromRouteStatic stack-based overflow
CVE-2024-38806.3 MEDIUMTenda W30E WriteFacMac formWriteFacMac os command injection