Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2023-1487— Lespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial of service

CVSS 5.5 · Medium EPSS 0.10% · P27
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2023-1487

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Lespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial of service
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability, which was classified as problematic, has been found in Lespeed WiseCleaner Wise System Monitor 1.5.3.54. This issue affects the function 0x9C40208C/0x9C402000/0x9C402084/0x9C402088/0x9C402004/0x9C4060C4/0x9C4060CC/0x9C4060D0/0x9C4060D4/0x9C40A0DC/0x9C40A0D8/0x9C40A0DC/0x9C40A0E0 in the library WiseHDInfo64.dll of the component IoControlCode Handler. The manipulation leads to denial of service. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The identifier VDB-223373 was assigned to this vulnerability.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
不恰当的资源关闭或释放
Source: NVD (National Vulnerability Database)
Vulnerability Title
Lespeed Technology WiseCleaner Wise System Monitor 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Lespeed Technology WiseCleaner Wise System Monitor是Lespeed Technology公司的一个免费且易于使用的 Windows 系统监控工具。有助于监控进程、硬件、网络流量、内存和其他内容。 Lespeed WiseCleaner Wise System Monitor 1.5.3.54 版本存在安全漏洞,该漏洞源于 IoControlCode Handler 组件的 WiseHDInfo64.dll 可能导致拒绝服务。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
LespeedWiseCleaner Wise System Monitor 1.5.3.54 -

II. Public POCs for CVE-2023-1487

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2023-1487

登录查看更多情报信息。

Same Patch Batch · Lespeed · 2023-03-18 · 4 CVEs total

CVE-2023-14897.8 HIGHLespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C402088 access c
CVE-2023-14864.4 MEDIUMLespeed WiseCleaner Wise Force Deleter IoControlCode WiseUnlock64.sys 0x220004 access cont
CVE-2023-14883.3 LOWLespeed WiseCleaner Wise System Monitor IoControlCode WiseHDInfo64.dll 0x9C40A0E0 denial o

IV. Related Vulnerabilities

V. Comments for CVE-2023-1487

No comments yet


Leave a comment