Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2022-45789

CVSS 8.1 · High EPSS 0.06% · P20
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2022-45789

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions)
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
使用捕获-重放进行的认证绕过
Source: NVD (National Vulnerability Database)
Vulnerability Title
Schneider Electric EcoStruxure Control Expert 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric EcoStruxure Control Expert(前称Unity Pro)是法国施耐德电气(Schneider Electric)公司的一套用于Schneider Electric逻辑控制器产品的编程软件。 Schneider Electric EcoStruxure Control Expert 存在安全漏洞,该漏洞源于存在通过捕获重放绕过身份验证漏洞,当劫持经过身份验证的会话时,可能会导致在控制器上执行未经授权的功能。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

II. Public POCs for CVE-2022-45789

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-45789

登录查看更多情报信息。

Same Patch Batch · Schneider Electric · 2023-01-31 · 3 CVEs total

CVE-2023-226109.1 CRITICALEcoStruxure Geo SCADA Expert 安全漏洞
CVE-2023-226117.5 HIGHEcoStruxure Geo SCADA Expert 信息泄露漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2022-45789

No comments yet