I. Basic Information for CVE-2022-44457

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions < V1.17.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.0 < V1.17.2), Mendix SAML (Mendix 8 compatible) (All versions < V2.3.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.2), Mendix SAML (Mendix 9 compatible, New Track) (All versions < V3.3.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.3.5), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions < V3.3.0), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.4). Affected versions of the module insufficiently protect from packet capture replay, only when the not recommended, non default configuration option `'Allow Idp Initiated Authentication'` is enabled. This CVE entry describes the incomplete fix for CVE-2022-37011 in a specific non default configuration.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
使用捕获-重放进行的认证绕过
Source: NVD (National Vulnerability Database)
Vulnerability Title
Siemens Mendix SAML Module 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Mendix SAML Module是德国西门子(Siemens)公司的一个应用程序模块。用于根据最终用户在您的身份提供者中的身份授予对 Mendix 应用程序的访问权限。 Siemens Mendix SAML Module 存在安全漏洞,该漏洞源于当启用了不推荐的非默认配置选项“允许 Idp 发起的身份验证”时,受影响的模块版本不足以防止数据包捕获重放,以下产品和版本受到影响:Mendix SAML 模块(Mendix 7 兼容)(V1.17.0之前版本)、Mendix SAML 模块
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
SiemensMendix SAML (Mendix 7 compatible) All versions < V1.17.0 -
SiemensMendix SAML (Mendix 7 compatible) All versions >= V1.17.0 < V1.17.2 -
SiemensMendix SAML (Mendix 8 compatible) All versions < V2.3.0 -
SiemensMendix SAML (Mendix 8 compatible) All versions >= V2.3.0 < V2.3.2 -
SiemensMendix SAML (Mendix 9 compatible, New Track) All versions < V3.3.1 -
SiemensMendix SAML (Mendix 9 compatible, New Track) All versions >= V3.3.1 < V3.3.5 -
SiemensMendix SAML (Mendix 9 compatible, Upgrade Track) All versions < V3.3.0 -
SiemensMendix SAML (Mendix 9 compatible, Upgrade Track) All versions >= V3.3.0 < V3.3.4 -

II. Public POCs for CVE-2022-44457

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-44457

登录查看更多情报信息。

Same Patch Batch · Siemens · 2022-11-08 · 15 CVEs total

CVE-2022-434399.9 CRITICALSiemens Power Meter Sicam Q100 输入验证错误漏洞
CVE-2022-435459.9 CRITICALSiemens Power Meter Sicam Q100 输入验证错误漏洞
CVE-2022-435469.9 CRITICALSiemens Power Meter Sicam Q100 输入验证错误漏洞
CVE-2022-391367.8 HIGHSiemens JT2Go和Teamcenter Visualization 缓冲区错误漏洞
CVE-2022-391577.8 HIGHSiemens Parasolid 缓冲区错误漏洞
CVE-2022-416607.8 HIGHSiemens JT2Go和Teamcenter Visualization 缓冲区错误漏洞
CVE-2022-416617.8 HIGHSiemens JT2Go和Teamcenter Visualization 缓冲区错误漏洞
CVE-2022-416627.8 HIGHSiemens JT2Go和Teamcenter Visualization 缓冲区错误漏洞
CVE-2022-416637.8 HIGHSiemens JT2Go和Teamcenter 资源管理错误漏洞
CVE-2022-416647.8 HIGHSiemens JT2Go和Teamcenter Visualization 缓冲区错误漏洞
CVE-2022-433977.8 HIGHSiemens Parasolid 缓冲区错误漏洞
CVE-2022-439587.6 HIGHSiemens Quality Management System 安全漏洞
CVE-2022-433987.5 HIGHSiemens Power Meter Sicam Q100 授权问题漏洞
CVE-2022-306946.5 MEDIUMSiemens SIMATIC Drive Controller跨站请求伪造漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2022-44457

No comments yet


Leave a comment