Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2022-24310

EPSS 1.98% · P84
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2022-24310

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
整数溢出或超界折返
Source: NVD (National Vulnerability Database)
Vulnerability Title
Interactive Graphical SCADA System Data Server 输入验证错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Schneider Electric Interactive Graphical SCADA System(IGSS)是法国施耐德电气(Schneider Electric)公司的一套用于监控和控制工业过程的SCADA(数据采集与监控系统)系统。 Schneider Electric Interactive Graphical SCADA System Data Server存在输入验证错误漏洞,该漏洞可能导致基于堆的缓冲区溢出,当攻击者利用该漏洞发送多个专门制作的消息时,会导致拒绝服务和潜在的远程代码执
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
-Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) -

II. Public POCs for CVE-2022-24310

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-24310

登录查看更多情报信息。

Same Patch Batch · n/a · 2022-02-09 · 115 CVEs total

CVE-2021-33110Intel Wireless Bluetooth 和 Killer Bluetooth 输入验证错误漏洞
CVE-2022-21156Intel Trace Analyzer And Collector 缓冲区错误漏洞
CVE-2021-44454Intel Quartus Prime Pro 输入验证错误漏洞
CVE-2022-21174Intel Quartus Prime Pro 安全漏洞
CVE-2022-21153Intel Capital Global Summit Android App 安全漏洞
CVE-2022-21133Intel Trace Analyzer And Collector 缓冲区错误漏洞
CVE-2021-33155Intel Wireless Bluetooth 和 Killer Bluetooth 输入验证错误漏洞
CVE-2021-33166Intel RXT for Chromebook 安全漏洞
CVE-2021-33129Intel Advisor 安全漏洞
CVE-2021-33139Intel Wireless Bluetooth 和 Killer Bluetooth 代码问题漏洞
CVE-2021-33137Intel Kernelflinger 缓冲区错误漏洞
CVE-2021-33147Intel Integrated Performance Primitives 代码问题漏洞
CVE-2021-33120Intel Processors BIOS firmware 缓冲区错误漏洞
CVE-2021-33119Intel RealSense Depth Camera Manager 安全漏洞
CVE-2021-33114Intel PROSet/Wireless WiFi Software 输入验证错误漏洞
CVE-2021-33068Intel 多款产品代码问题漏洞
CVE-2021-23152Intel Advisor 安全漏洞
CVE-2021-0178Intel 多款产品输入验证错误漏洞
CVE-2021-0183Intel 多款产品输入验证错误漏洞
CVE-2021-33061Intel 82599 Ethernet Series 安全漏洞

Showing top 20 of 115 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2022-24310

No comments yet


Leave a comment