Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2022-22172— Junos OS and Junos OS Evolved: An l2cpd memory leak can occur when specific LLDP packets are received leading to a DoS

CVSS 6.5 · Medium EPSS 0.08% · P24
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2022-22172

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Junos OS and Junos OS Evolved: An l2cpd memory leak can occur when specific LLDP packets are received leading to a DoS
Source: NVD (National Vulnerability Database)
Vulnerability Description
A Missing Release of Memory after Effective Lifetime vulnerability in the Layer-2 control protocols daemon (l2cpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated adjacent attacker to cause a memory leak. Continued exploitation can lead to memory exhaustion and thereby a Denial of Service (DoS). This issue occurs when specific LLDP packets are received. The impact of the l2cpd cores is that if any of the stp protocols (rstp, mstp or vstp) is used then stp re-converges and traffic loss will occur during that time. Also if any services depend on LLDP state (like PoE or VoIP device recognition) then these will also be affected. The memory utilization of the L2CPd process can be monitored with the following command: user@host> show system processes extensive | match l2cpd 1234 root 52 0 521M 43412K RUN 1 4:02 34.47% l2cpd This issue affects: Juniper Networks Junos OS 18.4 version 18.4R2-S4 and later versions prior to 18.4R2-S10. 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2-S2, 21.1R3; 21.2 versions prior to 21.2R2; Juniper Networks Junos OS Evolved All versions prior to 20.4R3-S2-EVO; 21.1 version 21.1R1-EVO and later versions; 21.2 versions prior to 21.2R2-EVO. This issue does not affect: Juniper Networks Junos OS 19.1 version 19.1R1 and later versions.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
在移除最后引用时对内存的释放不恰当(内存泄露)
Source: NVD (National Vulnerability Database)
Vulnerability Title
Juniper Networks Junos OS 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Juniper Networks Junos OS是美国瞻博网络(Juniper Networks)公司的一套专用于该公司的硬件设备的网络操作系统。该操作系统提供了安全编程接口和Junos SDK。 Juniper Networks Junos OS存在安全漏洞,该漏洞源于第2层控制协议守护程序(l2cpd)内存泄漏。攻击者可利用该漏洞对目标系统执行DoS攻击。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Juniper NetworksJunos OS unspecified ~ 18.4R2-S4 -
Juniper NetworksJunos OS Evolved unspecified ~ 20.4R3-S2-EVO -

II. Public POCs for CVE-2022-22172

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2022-22172

登录查看更多情报信息。

Same Patch Batch · Juniper Networks · 2022-01-19 · 27 CVEs total

CVE-2022-221527.7 HIGHContrail Service Orchestration: Tenants able to see other tenants policies via REST API in
CVE-2022-221537.5 HIGHSRX Series and MX Series with SPC3: A high percentage of fragments might lead to high late
CVE-2022-221807.5 HIGHJunos OS: EX2300 Series, EX2300-MP Series, EX3400 Series: A slow memory leak due to proces
CVE-2022-221787.5 HIGHJunos OS: MX and SRX series: Flowd core observed if the SIP ALG is enabled and a specific
CVE-2022-221757.5 HIGHJunos OS: MX Series and SRX Series: The flowd daemon will crash if the SIP ALG is enabled
CVE-2022-221747.5 HIGHJunos OS: QFX5000 Series, EX4600: Device may run out of memory, causing traffic loss, upon
CVE-2022-221737.5 HIGHJunos OS: CRL failing to download causes a memory leak and ultimately a DoS
CVE-2022-221717.5 HIGHJunos OS: Specific packets over VXLAN cause FPC reset
CVE-2022-221707.5 HIGHJunos OS: Specific packets over VXLAN cause FPC memory leak and ultimately reset
CVE-2022-221597.5 HIGHJunos OS: An attacker sending crafted packets can cause a traffic and CPU Denial of Servic
CVE-2022-221617.5 HIGHJunos OS: MX104 might become unresponsive if the out-of-band management port receives a fl
CVE-2022-221637.4 HIGHJunos OS: jdhcpd crashes upon receipt of a specific DHCPv6 packet
CVE-2022-221767.4 HIGHJunos OS: In a scenario with dhcp-security and option-82 configured jdhcpd crashes upon re
CVE-2022-221627.3 HIGHJunos OS: A low privileged user can elevate their privileges to the ones of the highest pr
CVE-2022-221677.2 HIGHJunos OS: SRX Series: If no-syn-check is enabled, traffic classified as UNKNOWN gets permi
CVE-2022-221577.2 HIGHJunos OS: SRX Series: Traffic classification vulnerability when 'no-syn-check' is enabled
CVE-2022-221546.8 MEDIUMJunos Fusion: A Satellite Device can be controlled by rewiring it to a foreign AD causing
CVE-2022-221606.5 MEDIUMJunos OS: MX Series: The bbe-smgd process crashes if an unsupported configuration exists a
CVE-2022-221686.5 MEDIUMJunos OS: vMX and MX150: Specific packets might cause a memory leak and eventually an FPC
CVE-2022-221566.5 MEDIUMJunos OS: Certificate validation is skipped when fetching system scripts from a HTTPS URL

Showing top 20 of 27 CVEs. View all on vendor page → →