Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2019-13927

EPSS 0.59% · P69
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2019-13927

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability has been identified in Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D with Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U with Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 (All firmware versions < V6.00.320), Desigo PX automation controllers PXC22.1-E.D, PXC36-E.D, PXC36.1-E.D with activated web server (All firmware versions < V6.00.320). The device contains a vulnerability that could allow an attacker to cause a denial of service condition on the device's web server by sending a specially crafted HTTP message to the web server port (tcp/80). The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device's web service. While the device itself stays operational, the web server responds with HTTP status code 404 (Not found) to any further request. A reboot is required to recover the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
对假设不可变Web参数的外部可控制
Source: NVD (National Vulnerability Database)
Vulnerability Title
Siemens Desigo PX 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Siemens Desigo PX是德国西门子(Siemens)公司的一套楼宇自动化控制系统。 Siemens Desigo PX中存在安全漏洞。远程攻击者可利用该漏洞造成拒绝服务。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

II. Public POCs for CVE-2019-13927

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-13927

登录查看更多情报信息。

Same Patch Batch · Siemens AG · 2019-12-12 · 8 CVEs total

CVE-2019-13930Siemens XHQ Operations Intelligence 跨站请求伪造漏洞
CVE-2019-13931Siemens XHQ Operations Intelligence 跨站脚本漏洞
CVE-2019-13932Siemens XHQ Operations Intelligence 安全漏洞
CVE-2019-13942Siemens EN100 Ethernet Module 缓冲区错误漏洞
CVE-2019-13943Siemens EN100 Ethernet Module 跨站脚本漏洞
CVE-2019-13944Siemens EN100 Ethernet module 路径遍历漏洞
CVE-2019-13945Siemens SIMATIC S7-200和S7-1200 输入验证错误漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2019-13927

No comments yet


Leave a comment