Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2019-11891— Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)

EPSS 0.11% · P29
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2019-11891

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
Source: NVD (National Vulnerability Database)
Vulnerability Description
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
特权授予不正确
Source: NVD (National Vulnerability Database)
Vulnerability Title
Bosch Smart Home Controller 权限许可和访问控制问题漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Bosch Smart Home Controller(SHC)是德国博世(Bosch)公司的一款智能家居控制设备。 Bosch SHC 9.8.905之前版本中的软件配对机制存在安全漏洞。攻击者可利用该漏洞提升权限。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
BoschSmart Home Controller unspecified ~ 9.8.905 -

II. Public POCs for CVE-2019-11891

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2019-11891

登录查看更多情报信息。

Same Patch Batch · Bosch · 2019-05-29 · 6 CVEs total

CVE-2019-11892Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
CVE-2019-11893Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Co
CVE-2019-11894Improper access control in the backup mechanism of the Bosch Smart Home Controller (SHC)
CVE-2019-11895Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)
CVE-2019-11896Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home C