Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2018-8870— Medtronic MyCareLink Patient Monitor Use of Hard-coded Password

CVSS 6.4 · Medium EPSS 0.04% · P13
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2018-8870

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
Medtronic MyCareLink Patient Monitor Use of Hard-coded Password
Source: NVD (National Vulnerability Database)
Vulnerability Description
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
Source: NVD (National Vulnerability Database)
CVSS Information
CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Source: NVD (National Vulnerability Database)
Vulnerability Type
使用硬编码的口令
Source: NVD (National Vulnerability Database)
Vulnerability Title
Medtronic MyCareLink Patient Monitor、24950 MyCareLink Monitor和24952 MyCareLink Monitor 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Medtronic MyCareLink Patient Monitor、24950 MyCareLink Monitor和24952 MyCareLink Monitor都是美国Medtronic公司的用于监测病人生命体征的监护仪设备。 Medtronic MyCareLink Patient Monitor、24950 MyCareLink Monitor所有版本以及24952 MyCareLink Monitor所有版本中存在安全漏洞,该漏洞源于程序使用了硬编码密码。物理位置临近的攻击者可利用该漏洞
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
Medtronic24950 MyCareLink Monitor All versions -
Medtronic24952 MyCareLink Monitor All versions -

II. Public POCs for CVE-2018-8870

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2018-8870

登录查看更多情报信息。

Same Patch Batch · Medtronic · 2018-07-02 · 3 CVEs total

CVE-2018-105967.1 HIGHMedtronic 2090 Carelink Programmer Improper Restriction of Communication Channel to Intend
CVE-2018-88686.2 MEDIUMMedtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function

IV. Related Vulnerabilities