Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2018-0270

EPSS 0.19% · P41
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2018-0270

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A vulnerability in the web-based management interface of Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack and alter the data of existing users and groups on an affected device. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. If the user has administrative privileges, the attacker could create a new, privileged account to obtain full control over the device interface. This vulnerability affects Connected Grid Network Management System, if running a software release prior to IoT-FND Release 3.0; and IoT Field Network Director, if running a software release prior to IoT-FND Release 4.1.1-6 or 4.2.0-123. Cisco Bug IDs: CSCvi02448.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
跨站请求伪造(CSRF)
Source: NVD (National Vulnerability Database)
Vulnerability Title
Cisco IoT Field Network Director 跨站请求伪造漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Cisco IoT Field Network Director(IoT-FND)是美国思科(Cisco)公司的一套端到端的物联网管理系统。该系统具有设备管理、资产跟踪和智能计量等功能。 Cisco IoT-FND中的基于Web的管理界面存在跨站请求伪造漏洞,该漏洞源于程序没有对基于Web的管理界面执行充分的跨站请求伪造保护。远程攻击者可通过诱使用户打开恶意的链接利用该漏洞以该受影响用户的权限执行任意操作。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
-Cisco IoT Field Network Director Cisco IoT Field Network Director -

II. Public POCs for CVE-2018-0270

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2018-0270

登录查看更多情报信息。

Same Patch Batch · n/a · 2018-05-17 · 41 CVEs total

CVE-2018-0280Cisco Meeting Server 输入验证漏洞
CVE-2018-11230jbig2enc 安全漏洞
CVE-2018-11224Libav 安全漏洞
CVE-2018-11225libming 安全漏洞
CVE-2018-11226libming 安全漏洞
CVE-2018-0222Cisco Digital Network Architecture Center 安全漏洞
CVE-2018-0268Cisco Digital Network Architecture Center 安全漏洞
CVE-2018-0271Cisco Digital Network Architecture Center API gateway 授权问题漏洞
CVE-2018-0277Cisco Identity Services Engine 安全漏洞
CVE-2018-0279Cisco Enterprise NFV Infrastructure Software Secure Copy Protocol服务器输入验证错误漏洞
CVE-2018-10027ESTsoft ALZip 安全漏洞
CVE-2018-0289Cisco Identity Services Engine logs组件跨站脚本漏洞
CVE-2018-0290Cisco SocialMiner 资源管理错误漏洞
CVE-2018-0297Cisco Firepower Threat Defense detection引擎安全漏洞
CVE-2018-0323Cisco Enterprise NFV Infrastructure Software 路径遍历漏洞
CVE-2018-0324Cisco Enterprise NFV Infrastructure Software CLI 命令注入漏洞
CVE-2018-0325Cisco IP Phone 7800 Series和Cisco IP Phone 8800 Series 输入验证漏洞
CVE-2018-0326Cisco TelePresence Server Software Web UI 安全漏洞
CVE-2018-0327Cisco Identity Services Engine 跨站脚本漏洞
CVE-2018-0328Cisco Unified Communications Manager和Cisco Unified Presence 输入验证漏洞

Showing top 20 of 41 CVEs. View all on vendor page → →

IV. Related Vulnerabilities

V. Comments for CVE-2018-0270

No comments yet


Leave a comment