CVE-2017-9657

EPSS 0.36% · P58
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2017-9657

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
抛出异常的清理不恰当
Source: NVD (National Vulnerability Database)
Vulnerability Title
Philips IntelliVue MX40 Patient Worn Monitor 安全漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Philips IntelliVue MX40 Patient Worn Monitor是荷兰飞利浦(Philips)公司的一款医疗监护设备。 Philips IntelliVue MX40 Patient Worn Monitor B.06.18之前的版本(仅限WLAN)中存在安全漏洞。当设备运行在802.11 WLAN时,攻击者可利用该漏洞发布802.11 Wi-Fi管理命令,造成拒绝服务。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
PhilipsIntelliVue MX40 Patient Worn Monitor IntelliVue MX40 Patient Worn Monitor (WLAN only), all versions prior to Version B.06.18 -

II. Public POCs for CVE-2017-9657

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2017-9657

Please Login to view more intelligence information

IV. Related Vulnerabilities

V. Comments for CVE-2017-9657

No comments yet


Leave a comment