I. Basic Information for CVE-2017-14470

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information, modification of settings, or modification of ladder logic. An attacker can send unauthenticated packets to trigger this vulnerability. Required Keyswitch State: REMOTE or PROG or RUN Description: The value 0xffffffff is considered NaN for the Float data type. When a float is set to this value and used in the PLC, a fault is triggered. NOTE: This is not possible through RSLogix.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Title
Rockwell Automation Allen-Bradley PowerMonitor 1000 访问控制错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Rockwell Automation Allen-Bradley PowerMonitor 1000是美国罗克韦尔(Rockwell Automation)公司的一款电源监控设备。 Rockwell Automation Allen-Bradley PowerMonitor 1000 存在访问控制错误漏洞。远程攻击者可通过发送特制的数据包利用该漏洞执行写入和读取操作,进而泄露敏感信息,修改设置或梯形逻辑。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
TalosAllen Bradley Allen Bradley Micrologix 1400 Series B FRN 21.2, Allen Bradley Micrologix 1400 Series B FRN 21.0, Allen Bradley Micrologix 1400 Series B FRN 15 -

II. Public POCs for CVE-2017-14470

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2017-14470

登录查看更多情报信息。

Same Patch Batch · Talos · 2018-04-05 · 16 CVEs total

CVE-2017-12088Rockwell Automation Allen Bradley Micrologix 1400 Series B FRN 输入验证错误漏洞
CVE-2017-12089Rockwell Automation Allen Bradley Micrologix 1400 Series 资源管理错误漏洞
CVE-2017-12090Rockwell Automation Allen Bradley Micrologix 1400 Series B 安全漏洞
CVE-2017-12093Rockwell Automation Allen Bradley Micrologix 1400 Series B 资源管理错误漏洞
CVE-2017-14462Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14463Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14464Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14465Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14466Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14467Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错漏洞
CVE-2017-14468Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14469Rockwell Automation Allen-Bradley PowerMonitor 1000 访问控制错误漏洞
CVE-2017-14471Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14472Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞
CVE-2017-14473Rockwell Automation Allen Bradley Micrologix 1400 Series B 访问控制错误漏洞

IV. Related Vulnerabilities

V. Comments for CVE-2017-14470

No comments yet


Leave a comment