Goal Reached Thanks to every supporter — we hit 100%!

Goal: 1000 CNY · Raised: 1000 CNY

100.0%

CVE-2017-12718

EPSS 25.77% · P96
Get alerts for future matching vulnerabilitiesLog in to subscribe

I. Basic Information for CVE-2017-12718

Vulnerability Information

Have questions about the vulnerability? See if Shenlong's analysis helps!
View Shenlong Deep Dive ↗

Although we use advanced large model technology, its output may still contain inaccurate or outdated information.Shenlong tries to ensure data accuracy, but please verify and judge based on the actual situation.

Vulnerability Title
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Description
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Source: NVD (National Vulnerability Database)
CVSS Information
N/A
Source: NVD (National Vulnerability Database)
Vulnerability Type
未进行输入大小检查的缓冲区拷贝(传统缓冲区溢出)
Source: NVD (National Vulnerability Database)
Vulnerability Title
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 缓冲区错误漏洞
Source: CNNVD (China National Vulnerability Database)
Vulnerability Description
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump是英国史密斯医疗(Smiths Medical)公司的一款注射器输液泵。 Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1版本、1.5版本和1.6版本中存在缓冲区溢出漏洞,该漏洞源于程序没有检测输入缓存区的大小。远程攻击者可利用该漏洞在目标设备上执行任意代码。
Source: CNNVD (China National Vulnerability Database)
CVSS Information
N/A
Source: CNNVD (China National Vulnerability Database)
Vulnerability Type
N/A
Source: CNNVD (China National Vulnerability Database)

Affected Products

VendorProductAffected VersionsCPESubscribe
-Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump -

II. Public POCs for CVE-2017-12718

#POC DescriptionSource LinkShenlong Link
AI-Generated POCPremium

No public POC found.

Login to generate AI POC

III. Intelligence Information for CVE-2017-12718

登录查看更多情报信息。

Same Patch Batch · n/a · 2018-02-15 · 31 CVEs total

CVE-2017-18088Atlassian Bitbucket Server 输入验证漏洞
CVE-2018-0864Microsoft Project Server和SharePoint Enterprise Server 权限许可和访问控制漏洞
CVE-2018-0820Microsoft Windows kernel 权限许可和访问控制问题漏洞
CVE-2018-7057Steelcase RoomWizard 跨站脚本漏洞
CVE-2018-7056Steelcase RoomWizard 信息泄露漏洞
CVE-2018-7055Steelcase RoomWizard 安全漏洞
CVE-2018-54403S-Smart CODESYS和CODESYS runtime system 缓冲区错误漏洞
CVE-2017-18189Sound eXchange 安全漏洞
CVE-2017-12726Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12725Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12724Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12723Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12722Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12721Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 安全漏洞
CVE-2017-12720Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 访问控制错误漏洞
CVE-2018-5767Tenda AC15 输入验证漏洞
CVE-2018-7169shadow 安全特征问题漏洞
CVE-2018-7054Irssi 安全漏洞
CVE-2018-7053Irssi 安全漏洞
CVE-2018-7052Irssi 安全漏洞

Showing top 20 of 31 CVEs. View all on vendor page → →