Goal Reached Thanks to every supporter β€” we hit 100%!

Goal: 1000 CNY Β· Raised: 1000 CNY

100.0%

CVE-2020-37125 β€” AI Deep Analysis Summary

CVSS 9.8 Β· Critical

Q1What is this vulnerability? (Essence + Consequences)

🚨 **Essence**: Remote Command Injection in Edimax EW-7438RPn-v3 Mini. <br>πŸ’₯ **Consequences**: Attackers can execute arbitrary OS commands via the `/goform/mp` endpoint. Total device compromise is possible.

Q2Root Cause? (CWE/Flaw)

πŸ›‘οΈ **Root Cause**: CWE-78 (OS Command Injection). <br>πŸ” **Flaw**: The `/goform/mp` endpoint fails to properly sanitize user input, allowing malicious commands to be injected directly into the operating system.

Q3Who is affected? (Versions/Components)

πŸ“¦ **Affected Product**: Edimax EW-7438RPn Mini (Wireless Range Extender). <br>🏒 **Vendor**: EDIMAX Technology. <br>πŸ“… **Version**: Specifically **1.27** is confirmed vulnerable.

Q4What can hackers do? (Privileges/Data)

πŸ‘‘ **Privileges**: Full Remote Code Execution (RCE). <br>πŸ“‚ **Data**: High impact on Confidentiality, Integrity, and Availability (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Hackers gain full control.

Q5Is exploitation threshold high? (Auth/Config)

πŸ”“ **Threshold**: **LOW**. <br>🌐 **Auth**: No authentication required (PR:N). <br>πŸ“‘ **Access**: Network accessible (AV:N). <br>πŸ‘€ **Interaction**: No user interaction needed (UI:N). Easy to exploit remotely.

Q6Is there a public Exp? (PoC/Wild Exploitation)

πŸ’£ **Public Exploit**: **YES**. <br>πŸ”— **Source**: ExploitDB ID **48318** is available. <br>⚠️ **Status**: Wild exploitation is feasible since PoC code is public.

Q7How to self-check? (Features/Scanning)

πŸ” **Self-Check**: Scan for Edimax EW-7438RPn devices running firmware **1.27**. <br>πŸ“‘ **Target**: Check if the `/goform/mp` endpoint is reachable and vulnerable to command injection payloads.

Q8Is it fixed officially? (Patch/Mitigation)

🩹 **Official Fix**: Data does not explicitly list a patch link. <br>πŸ“ **Note**: Vendor advisory exists via VulnCheck. Users should check the official Edimax product page for firmware updates.

Q9What if no patch? (Workaround)

🚧 **Workaround**: If no patch is available, **disable remote management** features. <br>πŸ”’ **Network**: Isolate the device in a segmented VLAN. Block external access to the device's management interface.

Q10Is it urgent? (Priority Suggestion)

πŸ”₯ **Urgency**: **CRITICAL**. <br>⚑ **Priority**: Immediate action required. <br>πŸ“‰ **Risk**: High CVSS score + No Auth + Public Exploit = High likelihood of active exploitation. Patch or isolate immediately.